Production water covers mixing, washing, cooling, ice and boiler steam; it must meet drinking-water sanitary standards and contain nothing classed as najis.
Mains water requires retained test reports; private wells need protection distances, locked covers and scheduled testing; filter changes on purification units must be logged. Auditors review the latest cycle's reports, the sampling-point map and numbered taps.
Potable and recycled-water pipes need clear markings with no cross-connections, drains must not backflow into workshops, and the wastewater station sits at a height difference from production; cooling-tower drift risk is assessed too, and Purified water in direct product contact also requires conductivity logs and membrane-cleaning schedules, taps use non-manual switches, and floor drains keep their water seals with inspection logs; retain delivery receipts and report copies for purchased bulk purified water, as auditors may draw a glass to inspect its clarity and ask about cleaning frequency. The outage plan states how replacement water is verified. Nothing here constitutes a commitment regarding the audit outcome.